Malfunction
Nails driving failure rate is
too high.
No nails are driven, but the
fan is running.
No nails are driven, and the
fan is not running.
Possible cause
The tool is not perpendicular to
the working surface.
Wrong type of nails is used.
The working surface is too hard.
Frequent incorrect position of
the driving piston.
The nail push button was not
moved forward.
Nail transport is not working
anymore.
Fuel cell is empty.
Incorrect position of the driving
piston.
Frequent incorrect position of
the driving piston.
The tool doesn't drive due to a
dirty spark plug.
The high voltage cable for the
spark plug got loose.
Not enough nails in the
magazine.
The battery is discharged.
The electric cable of the fan
got loose.
Action to be taken
→ On even surfaces use the removable stand
to ensure correct contact. Pay special
attention to hold the tool perpendicular to
the surface.
→ Use nails suitable for the application.
→ Use a different fastening method.
→ Clean the tool as described in chapter 8.
→ Release the nail push button from locking
position to get it in contact with the nail
strips.
→ Check the nail strip, if damaged use a new
one. Clean the magazine and the nose
piece.
→ Insert a new fuel cell.
→ Remove the magazine and nose piece. Push
back the driving piston all the way into its
initial position.
→ Clean the tool as described in chapter 8.
→ Clean the tool as described in chapter 8.
→ Open the back of the tool and plug in the
high voltage cable again.
→ Load new nails into the magazine.
→ Change the battery with a fully charged one.
→ Open the back of the tool and plug in the fan
cable again.