D3- Programmable function settings
To enter in the settings, maintain the button SET 5 seconds. A «1» appears. Scroll with UP or DOWN until the
wanted function, then SET to enter in this function. Then, modify the value with UP or DOWN (Be carefull, if no
button is pressed for 5 seconds, the display goes out of the automatic settings mode).
LED
viewer
Options of Gate
1
opening direction
2
Automatic closing
There actions
of photocell/
3
safety edge/ loop
detector when
they detecting
4
Motor speed
The deceleration
5
setting for gate
moving
Deceleration
6
speed
(% full speed)
32
EN
Definition
Function
1-1
1-2
2-0
2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
3-1
3-2
3-3
4-1
4-2
4-3
4-4
5-1
5-2
5-3
5-4
5-5
6-1
6-2
6-3
6-4
Value
Clockwise opening
The function can adjust the direction
of gate opening. The factory setting
CounterClockwise
is « 1-1 ».
opening
No automatic
closing
5 seconds
15 seconds
This function allows to adjust the
gate closing automatic after the
30 seconds
paused time.
45 seconds
The factory setting is « 2-0 » : no
60 seconds
automatic closing
80 seconds
120 seconds
180 seconds
Do not modify
Slow
Middle
The factory setting is « 4-3 »
Fast
Very fast
75% of full distance
80%
85%
The factory setting is « 5-1 »
90%
95%
80%
60%
The factory setting is « 6-3 »
40%
25%
Description
The factory setting is « 3-1 »