5- Programming With Operation For Awnings - Vimar ELVOX ECG3 Manual Para El Conexionado Y El Uso

Tarjeta para mando de persianas o toldos
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 58
Terminal number
Description
7
GND common (COM)
8
Opening and stopping command (IN1)
9
Closing and stopping command (IN2)
10
Wind sensor input (IN3)
11
GND common (COM)
12
Light sensor input (IN4)
13
Rain sensor input (IN5)
14
Positive +12Vdc ( +12v)
If one or more sensors are missing, this will not affect the operation of the switchboard.
Sensor characteristics:
The wind sensor (anemometer) will be the non-powered type (there is usually a reed contact inside) and must be connected between terminals COM and IN3 of the terminal
block M1.
The sun sensor (photocell) will be the analogue type 4..20mA, powered at 12Vdc, and must be connected between terminals COM and IN4 of the terminal block M1. In ad-
dition, it will be necessary to respect the polarities.
The rain sensor will be the analogue type 4..20mA, powered at 12Vdc, and must be connected between terminals COM and IN5 of the terminal block M1. In addition, it will
be necessary to respect the polarities.
The rain sensor may be equipped with an internal heater to evaporate the water deposited after rainfall, connect the latter between terminals COM and +12V of the terminal
block M1.
5. Programming with operation for awnings (DIP switch 1 and 2 OFF)
The trip thresholds should be adjusted via the trimmers in the sensors (light and rain) or on the control board (wind sensor), the image summarises how to perform the cali-
bration for each sensor.
THRESHOLD
WIND
TO BE PERFOR-
MED WITH
SUSTAINED WIND
THRESHOLD
SUN
TO BE PERFOR-
MED WITH SUNRI-
SE OR SUNSET
THRESHOLD
RAIN
PERFORMED By A
SENSOR WET
It is absolutely necessary for there to be electromechanical limit switches that stop the motor
20
All manuals and user guides at all-guides.com
TURN THE TR1 TRIM TO
FIND THE SET POINT
RED
LED FLASHING CHA INDI-
CATE THE THRESHOLD
HAS BEEN OVER THERE
FLASH
SO THE TENT WILL CLO-
WIND SENSOR
SED
TURN
THE
INTERIOR
GREEN
TRIM TO FIND THE SET
POINT
LED
FLASHING
INDICATE THE THRE-
FLASH
SHOLD HAS BEEN OVER
THERE SO THE TENT
WILL OPEN
TURN
THE
INTERIOR
BLUE
TRIM TO FIND THE SET
POINT
LED
FLASHING
INDICATE THE THRE-
FLASH
SHOLD HAS BEEN OVER
THERE SO THE TENT
WILL CLOSED
WIND SENSOR
CHA
SUN SENSOR
CHA
RAIN SENSOR
EN

Publicidad