B
MACHINE AND MANUFACTURER IDENTIFICATION
PART NUMBER
TECHNICAL
DATA
MODEL:
127642 - 120/VAC 60 Hz
C
MACHINE DESCRIPTION
PUMP: Five-chamber positive-displacement diaphragm pump.
MOTOR: Asynchronous motor, single-phase, 2 pole, closed type, protection class IP55
according to CEI-EN 60034-5.
C.1
HANDLING AND TRANSPORT
Due to the limited weight and dimensions of the pumps, special lifting equipment is not
required to handle them. The pumps are carefully packed before dispatch. Check the
packing when receiving the material and store in a dry place.
GENERAL WARNINGS
D
Important pre-
cautions
Symbols used
in the manual
Manual preser-
vation
Reproduction
rights
E
FIRST AID RULES
Contact with
the fluid
Persons who
have suffered
electric shock
NOTE
M0307
Graco Inc.
P.O. Box 1441
Mpls, MN 5540 USA
Mpls, MN 55440
MADE IN ITALY
127642
F 14 A
XXXX
MAX WPR 345 kPa (3.4 bar)(50 psi)
120V
60 Hz
500 W
4.7A
1730 Rpm
DUTY CYCLE 20´ON/20´OFF
34 lpm/9 gpm
-5C to 40C 23F to 104F
IP55/RAINPROOF
LOT XXXXXXX
www.graco.com
Read instruction manual 333465.
Artwork No. 294248 Rev. B
To ensure operator safety and to protect the pump from
potential damage, workers must be fully acquainted with
this instruction manual before performing any operation.
The following symbols will be used throughout the manual
to highlight safety information and precautions of particular
importance:
WARNING
This symbol indicates safe working practices for
operators and/or potentially exposed persons.
NOTICE
This symbol indicates that there is risk of damage to
the equipment and/or its components.
NOTE
This symbol indicates useful information
This manual should be complete and legible throughout.
It should remain available to end users and specialist
installation and maintenance technicians for consultation at
any time.
All reproduction rights are reserved by Graco Inc. The text
cannot be reprinted without the written permission
In the event of problems developing following EYE/
SKIN CONTACT, INHALATION or INGESTION of the treated
product, please refer to the SAFETY DATA SHEET/ASU32 /
DEF / AD-Blue (ISO22241)
Disconnect the power source, or use a dry insulator to
protect yourself while you move the injured person away
from any electrical conductor. Avoid touching the injured
person with your bare hands until he is far away from any
conductor. Immediately call for help from qualified and
trained personnel. Do not operate switches with wet hands.
Please refer to the safety data sheet for the fluid
DATE CODE
EN
3