Understanding the Status Light
Color
Steady green
Slow flashing
green
Fast flashing
green
Flashing red
Steady red
No light
Specifications
Electrical requirements: x 5V, 1.8A
Operating temperature: 0°C to 35°C (32°F to 95°F)
Storage temperature:
Relative humidity:

Where to Find More Information

To download manuals, go to www.intermec.com. For Product
Support, go to intermec.custhelp.com or call 1-800-755-5505.
Description
Battery is fully charged.
Battery is quick charging. Quick charging
occurs for the first hour that the battery is in
the charger. After 1 hour, the battery is charged
to approximately 75% capacity.
Battery is charging. A fully discharged battery
charges to 100% capacity in approximately 4 hours.
The battery temperature is too cold or too hot
for the battery to charge. Make sure that the
temperature is from 0°C to 35°C (32°F to
The battery is not charging. For help, contact your
local Intermec service representative.
The charger is not operating. Make sure that the:
• SR61 is correctly inserted in the charger.
• power supply is properly connected to the
charger and an AC outlet.
• battery contacts are clean. To clean the contacts,
rub them with a pencil eraser and remove any
eraser debris.
-20°C to 60°C (-4°F to 140°F)
0% to 95% non-condensing
95
°F).
5