7. TECHNICAL SPECIFICATIONS
7.1.
TECHNICAL CHARACTERISTICS
Accuracy calculated as ±[%reading + (num. digits*resol)] referred to 18°C28°C,<70%RH
DC Voltage (Autorange)
Range
Resolution
400.0V
0.1V
600.0V
AC TRMS Voltage (Autorange)
Range
Resolution
400.0V
0.1V
600.0V
(*) Accuracy specified from 5% to 100% of the measurement range
Frequency range: 40Hz ÷ 1kHz (sinusoidal waveform) ; 40Hz ÷ 60Hz (not sinusoidal waveform)
DC Current (Autorange)
Range
Resolution
10.00A
0.01A
100.0A
0.1A
AC TRMS Current (Autorange)
Range
Resolution
10.00A
0.01A
100.0A
0.1A
(*) Accuracy specified from 5% to 100% of the measurement range
Frequency range: 40Hz ÷ 1kHz (sinusoidal waveform) ; 40Hz ÷ 60Hz (not sinusoidal waveform)
Resistance (Autorange)
Range
Resolution
40.0
0.1
400.0
4.000k
0.001k
40.00k
0.01k
400.0k
0.1k
Continuity test with buzzer
Function
Accuracy
(1.0%rdg+5dgt)
Accuracy (*)
(1.0%rdg+5dgt)
Accuracy
(3.0%rdg+15dgt)
(3.0%rdg+8dgt)
Accuracy (*)
(50Hz ÷ 60Hz)
(3.0%rdg+15dgt)
(3.0%rdg+8dgt)
Accuracy
(2.0%rdg+18dgt)
(2.0%rdg+10dgt)
Buzzer
<50
EN - 14
Input impedance
>10M
Ω
Input impedance
>9M
Ω
Protection against overcharge
600VDC/ACrms
Protection against overcharge
600VDC/ACrms
Protection against overcharge
600VDC/ACrms
Test current
<0.3mA
FLASHMETERPRO
Protection against
overcharge
600VDC/ACrms
Protection against
overcharge
600VDC/ACrms
Protection against
overcharge
600VDC/ACrms