Function of LOG Button
1
Press
Pressing
button while powering-up to select the mode – Data Logger mode,
Manual Saving mode and Clear memory.
Data Logger
The meter can store up to 4000 data in memory.
Press
button for more than 2 seconds to activate Data logger mode. The meter
will enter Time interval setting mode.
Press
button again to select time interval. The interval can be 1 second, 5
seconds, 10 seconds, 30 seconds, 60 seconds.
LOG
2 Sec
AC
V
Press
AC
LOG
V
LOG icon flashes while logging
All stored data will be cleared next startup. Download the stored data by App first if
needed.
2
LOG
LOG
LOG
Time interval setting mode
Press
LOG
LOG
>2Sec
2 Sec
LOG
Start to record auto
matically after 2sec
without operaction.