Disposal; Information To Users - TESY HPWH 2.1 260 U02 S Instrucciones De Uso Y Mantenimiento

Bomba de calor para agua caliente sanitaria
Ocultar thumbs Ver también para HPWH 2.1 260 U02 S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Over heat
protection
E3
(HTP Switch)
Solar thermal
collector high
E4
temp protection
Water flow
E5
failure
Defrosting
Defrost
indicate
Communication
E8
failure
When remote signal is on, no P7 will be showed on the controller, when remote signal is off, P7 will
be displayed. It is not an error code, but a situation for remote on/off signal.
WARNING! In the event that the operator does not succeed in solving the problem, switch off the
equipment and seek technical assistance specifying the device model purchased.

12. DISPOSAL.

At the end of their device lifecycle, the TESY heat pumps will be disposed of in conformity with the applicable regulations.
WARNING! This equipment contains greenhouse fluorinated gas included in the Kyoto protocol. The
maintenance and disposal operations must only be carried out by qualified personnel. This device
contains R134a refrigerant in the amount as stated in the specification. Do not vent R134a into the
atmosphere: R134a, is a fluorinated greenhouse gas with a Global Warming Potential (GWP) = 1975.

INFORMATION TO USERS:

Pursuant to EU Directives 2011/65/EU (RoHS), 2012/19/EU (WEEE), relating to the reduction of the use of hazardous
substances in electric and electronic equipment as well as waste disposal.
The symbol of the barred wheelie bin that can be seen either on the equipment or its packaging indicates that the device must
be collected separately from other waste at the end of its lifecycle.
☆☆☆☆☆☆☆☆●
(8 flashes 1 dark)
☆☆☆☆☆☆☆☆☆☆☆●(11flash1
dark)
☆☆☆☆☆☆☆☆☆●(9 flash
1dark)
☆☆☆☆☆☆☆☆...... (all long
flashes)
Bright
1) Too high tank
water temp
2) The switch
damaged
3) PCB board
failure
1)
solar water
circuit water
flow very little
or without
water flow
2)
Related
connecting
wires off
3)
Water pump
failure
4)
PCB board
failure
1) solar water
circuit water flow
very little or
without water flow
2) Related
connecting wires
off
3)water pump
failure
4)water flow switch
failure
5) PCB board
failure
29
1) If the tank water temp is
over 85C, the switch will open
and the unit will stop for
protection. After the water
comes to normal temp,
2) Replace a new switch
3) Change the PCB board
1)
Solar water circuit fluid
infusion and exhaust
2)
Related connecting wires
being reconnected
3)
Change the water pump
4)
change the PCB board
1) Solar water circuit fluid
infusion and exhaust
2) Related connecting wires
being reconnected
3) Change the water pump
4) Change the water flow
switch
5) Change the PCB board

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hpwh 2.1 260 u02Hpwh 2.1 200 u02 sHpwh 2.1 200 u02

Tabla de contenido