Cap
DC Sensor
Connector
Install The DC Sensor or Sensor Clip
NOTICE: Do not pinch or kink the wires between the cap and the
valve body. If the wires are damaged, the unit may not operate.
Hold the cap horizontally with the sensing holes down and align
the DC sensor with the cap.
Slide the DC sensor into the cap until the sensor eyes align with
the holes in the cap. Ensure the sensor wires are not pinched and
the DC sensor connector hangs free.
Slide the wedge clip between the DC sensor and the cap until
snug.
Connect the DC sensor connector to the solenoid connector on the
valve. Ensure that the connector pair is fully seated.
Locate the connector assembly adjacent to the sensor body to
prevent pinching when cap is reinstalled on the valve.
Place the cap on the valve body.
Align the sensor eyes toward the user.
Secure the cap with the setscrew.
Open the control stop valve (refer to the "Control Stop Valve
Operation" section).
Reinstall the stop cap onto the control stop and tighten firmly
with a strap wrench.
Verify that the valve functions.
Kohler Co.
Setscrew
DC Sensor
Wedge Clip
9
1104277-5-B