the associated dangers. Otherwise, there is a danger of operat-
ing errors and injuries.
Supervise children during use, cleaning and maintenance. This
will ensure that children do not play with the device.
The equipment must only be operated by qualified specialized
staff!
Read through this operating manual carefully; the strict observation of processes described in it
is a prerequisite for the safety of the operator, the perfect condition of the device and retention of
the stated performances.
Wear suitable protective clothing such as protective gloves and protective goggles. Contact with
refrigerants can lead to blindness or other damage to the health.
Only work at an adequate distance from flames and hot surfaces since the refrigerant gas de-
composes at high temperatures; in doing so poisonous and aggressive substances are released
which are dangerous to the health and which pollute the environment.
Avoid contact with the skin since the low evaporation temperature (about -30°C) can cause
freezing.
Avoid breathing in the refrigerant vapours.
Always ensure that the device is connected to a power supply network with suitable fuses and
functional earthing.
The device may only be operated in a well ventilated environment with an adequate air change
frequency.
Switch off the device and separate it from the power supply network when it is not needed.
If the power supply cable is damaged, it must be replaced by the manufacturer or its technical
assistance service or a similarly qualified person in order to avoid any hazard.
The recycling bottle and hoses used must be compliant with the local regulations.
2
Scope of delivery
1 refrigerant Recovery unit
1 power cable
1 filter
1 filter connection hose
1 OFP cable for DOT bottles (used in special countries)
1 carrying belt
1 manual in various languages
3
Technical Data
Voltage ..............................................................
Output................................................................
Refrigerant classes ............................................
Voltage ..............................................................
Dimensions (L x W x H) ................................ 3 70 x 250 x 360 mm
Weight ............................................................ ca. 12 Kg
Refrigerants .......................................................
Extraction rate ...................................................
12
220-240 V, 50/60 Hz
0,74 kW
A1, A2L, A2
¼" SAE
Category III: R12, R134a, R406A, R1234yf...
Category IV: R22, R407C, R502, R509...
Category V: R404A, R407A, R410A, R32
Gaseous 0,5 kg/min (R410A)
Liquid: 3,5 kg/min (R410A)
Push/Pull: 9,5 kg/min (R410A)
ENGLISH