Connecting and installing the system
7.3
Connecting and installing the control box
➤ Screw the control box in place at a suitable location using four screws.
Connections
No. in
fig. 4,
Description
page 5
1
2
IBS_B1
3
IBS_B2B
4
IBS_B2A CI bus
5
CI bus
6
CI bus
7
8
9
10
11
12
13
14
15
16, 17
18
F1 – F7
19
E1 – E17
14
Explanation
Connection for display
Connection for supply battery B
Connection for supply battery A
Connection for starter battery
Connection for MCA chargers
Connection for devices communicating with the CI bus
Connection for step button
Connection for waste water tank probe
Connection for fresh water tank probe
Connection for external temperature sensor
Connection for internal temperature sensor
Earth connection for consumer unit and starter battery
Connection for consumer unit battery
Connection for starter battery
Connection for side light and D+
When connecting the D+ signal, the starter and consumer
unit battery (amongst other units) are interconnected via a
relay on the board of the control box.
Compressor wire bridge
If a wire bridge is set, the refrigerator is permanently
supplied with 12 V voltage. Without a wire bridge, the
refrigerator is only supplied with voltage if the vehicle is in
operation (D+ is applied).
The cross section of the wire bridge must be designed
corresponding to the current of the refrigerator.
Fuses
Outputs for consumer units
See following table