CONTROL PANEL FEATURES
16
16. Propane/LPG inlet.
17. Output Ready Indicator LED (Green):
when the generator is operating normally and indicates the
generator is producing electrical power at the receptacles.
18. Overload Indicator LED (Red):
generator is overloaded which means the generator's
wattage / amperage capacity has been exceeded by
connected electrical devices or by a power surge.When
this occurs, the Output Ready Indicator LED will go off.
The engine will continue to run, but the red Overload
Indicator LED will stay on, and power will no longer be
supplied to connected electrical devices.
To rest the generator:Remove all applied loads and stop
the engine. Review for any faulty or shorted connections.
Start the generator and reconnect electrical devices
sequentially, allowing the generator to stabilize after each
device is connected. Make sure the total wattage of
connected electric devices are not exceeding recommended
rated output power.
17 18 19
Illuminates
Illuminates when the
Page 11
19. Oil Warning Indicator LED (Red):
when the engine oil level falls below the safe operating
level and the generator will automatically shut off the
engine. The engine will not start until the proper
amount of oil is in the crankcase.