Direction
Delay Time
Target Thread
Target Torque
Hi Torque Kg.cm
Lo Torque Kg.cm
Hi Thread
Lo Thread
SCREW SETTING
Name
Screw Sequence
Screw Name
Screw Reverse
Sequence 1
Sequence 2
Sequence 3
Sequence 4
Sequence 5
OK ALL Holding
Time
OK One Holding
Time
48
CW/CCW
0.0~9.9
000.1~999.9
Please refer to the
specification of
screwdrivers
000.01~499.99
000.00~499.98
000.1~999.9
000.0~999.8
Set Up
Value
01~99
Setup screw parameter name. It can choose
******
number, capitals and lower case letters,
001~250
001~250
000~250
000~250
000~250
000~250
0.0~9.9
AT: OK ALL signal holding time
0.0~9.9
Setup rotation
direction
Setup interval time
between screws
Setup target nº. of
thread
Setup target torque
Setup max. torque
value
Setup min. torque
value
Setup max. thread
value
Setup min. thread
value
Function Description
Setup screw parameter.
number.
Setup screw reverse strategy
Setup 1
sequence
st
Setup 2
sequence
nd
Setup 3
sequence
rd
Setup 4
sequence
th
Setup 5
sequence
th
OT: OK signal holding time
CW
0.8
005.0
Please refer to the
specification of
screwdrivers
005.00
000.00
999.9
000.0
Default
setting
01
******
01
01
00
00
00
00
1.0
9.9