The pump capacity of the pump depends on the lifting
height, hose diameter and hose length.
1. Observe max. lifting height, see technical data, if
necessary select other hose diameter or other hose
length.
The circuit breaker of the HP pump has triggered
The current of the pump was too high.
1. Push the button on the back of the edge bracket
holder of the circuit breaker back in so that the circuit
breaker is reset.
2. Pump can be started again.

Technical data

Electrical connection
Voltage
Nominal power
Device performance data
Maximum flow rate
Pressure (max.)
Delivery height (max.)
Particle size (max.) of permissible
feed fluids
Dimensions and weights
Weight (without accessories)
Subject to technical modifications.

Pump characteristic curve

The possible flow rate is further increased:
● The lower the suction and lifting heights are.
● The greater the diameter of the hoses used is.
● The shorter the hoses used.
● The smaller the pressure loss caused by the con-
nected up accessories.
12
BP
2.000-18
Barrel
V
18
W
80
l/h
2000
MPa
0,20
(bar)
(2,0)
m
20
mm
0,5
kg
1,1
English

EU Declaration of Conformity

EU Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements in the EU Directives, both in its basic design
and construction as well as in the version placed in cir-
culation by us. This declaration is invalidated by any
changes made to the machine that are not approved by
us.
Product: Pump battery
Type: BP 2.000-18
Currently applicable EU Directives
2014/35/EU
2014/30/EU
2011/65/EU
Harmonised standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN IEC 63000: 2018
The signatories act on behalf of and with the authority of
the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2022/01/01
Declaration of Conformity (UK)
We hereby declare that the product described below
complies with the relevant provisions of the following
UK Regulations, both in its basic design and construc-
tion as well as in the version put into circulation by us.
This declaration shall cease to be valid if the product is
modified without our prior approval.
Product: Pump battery
Type: BP 2.000-18
Currently applicable UK Regulations
S.I. 2016/1101 (as amended)
S.I. 2016/1091 (as amended)
S.I. 2012/3032 (as amended)
Designated standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN IEC 63000: 2018
The signatories act on behalf of and with the authority of
the company management.