Loop Mode.
A single Program or all Programs can be set to have the irrigation cycle repeat itself
in loop.
The Program that works in Loop has only 1 Start Time a day.
Once started the Program's irrigation cycle will repeat itself in a loop until a Stop
Time is reached.
Once the Stop Time is reached the last irrigation cycle will be completed.
At the end of any single irrigation cycle a Delay between cycles can be set.
Important Note: if the Start Time is not OFF and the Stop Time is OFF, the program set
to run in Loop Mode will run forever.
Setting Loop Mode.
• Press the
button to access the Controller's Settings.
• Press the
or
buttons to select LOOP MODE.
• Press the
or
button to select ALL 4 Programs (A, B, C, D) or ONLY one of
them:
Program A, or
Program B, or
Program C, or
Program D, or
ALL.
Controller Operation
The LIFE Plus Controller has five modes of operation:
Automatic
, Manual Station(s) , Manual Program(s) , Test
(Off)
.
In the Automatic mode, the controller tracks the time and day and operates the
automatic watering schedules as programmed. The Manual Station(s) mode enables
an individual station to be started and controlled manually. Manual Program(s)
mode enables watering programs to be started manually. Test mode enables a quick,
temporary, program to be run to test the operation of each station control valve
and a quick test of the electrical network. The Pause(Off) mode prevents all station
operation.
Priority for modes of operation:
1. Entering Pause(Off) mode of operation will stop and prevent from being entered
Test, Manual Station(s), Manual Program(s) and Automatic watering schedules.
2. Entering the Test mode of operation will stop and prevent from being started,
Manual Program(s), Manual Station(s) and Automatic watering schedules.
3. Entering Manual Station(s) mode of operation will stop and prevent from being
started Manual Program(s) and Automatic watering schedules.
Note: in Pause(Off), Test and Manual Station(s) modes of operation, AUTO mode can
be entered just to show current time and date but no automatic watering schedule
will be allowed.
The display INFO will show PAUSE ON.
LIFE Plus Controller 4-8-12-16
and Pause
25