EGEA
200 LT - 260 LT - 200 LT-S - 260 LT-S
Incorrect installation can result in damage to property and injury to persons and animals; the manufacturer is not liable for
the consequences.
This product is heavy, handle with care and install the product in a frost-free room.
Ensure that the floor can support the weight of the water filled appliance.
The destruction of the appliance by overpressure due to the blocking of the safety device inactivates the warranty.
INSTALLATION WARNINGS
When installing this product in a bathroom do not use the "Prohibited space" and respect, at least, the "Protected space"
listed as shown below:
Prohibited space
Protected space
This product must be placed in an accessible location.
The water heater must be fixed to the ground using the fixing brackets provided for this purpose and adhesives are not
considered to be a reliable fixing means.
This product is designed to be used at a maximum altitude of 2000 m.
Refer to description and illustrations in paragraphs "6.1 Preparation of place of installation" on page 98 , "6.2 Securing
to the floor" on page 99 and "6.4 Securing and connections of this appliance" on page 101.
AERAULIC CONNECTIONS WARNINGS
The simultaneous operation of an open-chamber hearth (e.g. open fireplace) and the heat pump causes a dangerous
negative pressure in the room. The negative pressure can cause the return of exhaust gases into the room. Do not
operate the heat pump together with an open-chamber hearth. Only use sealed-chamber hearths (approved) with separate
combustion air supply. Seal the doors of boiler rooms that do not have the inflow of combustion air in common with living
areas. A suitable protection grille must be installed both at the air intake and outtake connections to prevent any foreign
bodies from going inside the equipment.
Refer to description and illustrations in the "6.3 Aeraulic connections" on page 99.
EN
88