CONNECTION TO THE ELECTRICITY SUPPLY

Electrical installations must be done by a qualified electrician.
The power supply must meet the specifications on the product.
The cores in the supply cable are coloured in accordance with the
following codes:
UK / EMEA:
Brown = Live
Blue = Neutral
Green / Yellow = Earth
Do not use the supply cable to lift the UV as this may cause damage.
WARNING - A Residual Current Device (RCD), also known as the Residual Current Circuit
Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the
supply circuit. A means of disconnection from the supply having a contact separation of at
least 3mm in all poles must be incorporated in the wiring.
Caution: Use in the area of a swimming pool only if the installation complies with the
relevant wiring regulations. Please consult a qualified electrician.
All electrical installations and wiring must be adequately protected to prevent
any damage.
Enough electrical cable is supplied with the unit to connect to the mains electric. This unit
must be connected to permanent wiring. A switch with 3mm contact separation must be
provided in the fixed wiring to provide disconnection from the electricity supply.
UV unit has to be wired in conjunction with the pump so that when the pump is turned
off, so is the UV unit.