Remove suction hose, close off the suction spigot with a plug.
Open the side latches, remove the top section.
Carefully pull the flange off the suction spigot and close off the flange.
Dispose of the vacuumed up material in accordance with legal requirements.
Insert fleece filter bag:
Note: Only use fleece filter bags for dry vacuum cleaning.
Slide the flange completely over the suction aperture.
Place the upper section on the container and close the side latches.
3.7
Changing the filter
Changing the folding filter:
Shake the folding filter cassettes before changing them.
Turn the lock on the latch through 90° in a counter-clockwise direction with a coin or similar
object and push the latch to the rear.
Fold the hood up.
Immediately isolate the folding filter cassettes that you have removed in a dust-tight plastic
bag and dispose of properly in accordance with the stipulations.
Insert new folding filter cassettes.
Lift the locking bracket up, fold the hood down and click in place with light pressure.
3.8
Changing the motor protection filter
Note: If the motor protection filter is contaminated this indicates defective filter cassettes.
Replacing the folding filter cassettes.
Replace the motor protection filter or wash the motor protection filter under flowing water,
dry and re-insert.
3.9
Transport
The motor head must be securely fixed to the container (close the latches).
Place the accessories in a suitable plastic bag and seal the plastic bag or place it in the tool
storage compartment.
Plug the ends of the suction hose into each other.
Place the hose around the vacuum cleaner and clamp onto the handle.
4
Maintenance
Switch the vacuum cleaner off and pull out the mains plug before any maintenance work!
For maintenance by the user, the vacuum cleaner must be
-- dismantled,
-- cleaned and
-- maintained,
as far as possible without creating any danger to the maintenance personnel or other.
Precautionary measures:
Suitable precautionary measures include
-- Cleaning before dismantling,
-- Provide local filtered positive ventilation where the vacuum cleaner is to be dismantled,
-- Clean the maintenance area and
-- suitable personal protection equipment
Note: Operating the rotary slider:
Push the rotary slider from the inside to the outside, turn through
180° (see mark) and then push inwards again from the outside
through the suction spigot.
Place the rotary slider in the suction aperture with the mark ▲
pointing upwards.