The dust that arises when working with this tool can be detrimental to health and therefore not
reach the body. Wear a suitable dust protection mask.
Always disconnect the plug from the socket before carrying out any work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine. Always lead the cable away behind
you.
When working in walls ceiling, or floor, take care to avoid electric cables and gas or water pipes.
Do not touch a damaged or severed power supply cord when working; pull the plug out of the
power socket immediately instead. Never operate the device with a damaged power supply
cord.
Before beginning your work consult the responsible structural designer to establish the exact
position of the hole to be drilled.
When drilling through a ceiling secure the area from below because the diamond core bit can fall
out.
2
Technical Data
Voltage .......................................................
Nominal power output ................................
No-load speed ...................................................
Speed under load ................................ 1150 min
Oscillation ..........................................................
Drilling capacity in concrete ...............................
Tool reception ....................................................
Weight ...............................................................
Operator safety coupling ................................
Protection class .................................................
Type of protection ................................ IP 20
Noise pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 62841-1.
Vibration total value ................................
The Vibration Total Value quoted in these instructions and the quoted noise emission values
were measured according to standardized measurement procedures and can be used to com-
pare one electric power tool with another. They can also be used to make an initial estimate of
the loading.
The quoted vibration and noise emissions can vary during actual use of the electric
power tool dependent on the way in which the electric power tool is used, in particular
what type of workpiece is being processed. Establish additional safety measures to
protect the operator which are based upon an estimate of the vibration loading during the actual
usage conditions (in doing so taking account of parts of the operating cycle, for example times in
which the electric power tool is switched and those in which it is switched on but not running
under load).
3
Electric supply
Connect only to single-phase a.c. current and only to the system voltage indicated on the rating
plate.
It is also possible to connect to sockets without an earthing contact as the design conforms to
safety class II.
230 V a.c. , 50 Hz
1800 W
1800 min
28000 min
32 – 202 mm
1.1/4" UNC + G 1/2"
approx. 5,5 kg
yes, electronic limit
II /
) ...........................
92 dB (A) ¦ K
pA
) .............................
103 dB (A) ¦ K
WA
5,5 m/s
ENGLISH
-1
-1
-1
3 dB (A)
pA
3 dB (A)
WA
2
¦ K= 1,5m/s
2
11