shop solvent. Remaining dye could be mistaken for a leak. Check all areas again
with the lamp to make sure no dye remains. Run the system for another 5 to 10
minutes and reinspect with the LeakTracker™ Plus. No glow means that all leaks
have been properly repaired.
REPLACING THE BATTERIES: Turn the end cap counterclockwise to gain
access to the batteries. Remove the three C alkaline batteries and install three
new batteries– with the positive-end facing forward – into the lamp housing.
Secure the end cap and test the lamp.
ENVIRONMENTAL SPECIFICATIONS:
The LeakTracker™ Plus lamp is designed to be safe under the following
conditions:
•
For Indoor/Outdoor Use (dustproof and protected against water
pressure)
•
Temperature 41°F to 122°F (5°C to 50°C)
WARRANTY/ REGISTRATION:
To review the warranty policy:
spectroline.com/warranty
To register the product online:
spectroline.com/warranty Registration
NOTE: For assistance of any kind, contact the Customer Service Department at
Spectronics. Give the model and serial numbers of the unit and the date of
purchase. To read the serial number, open the tail cap of the lamp and remove
the battery stick. The serial number label is inside the barrel of the lamp.
TECHNICAL SPECIFICATIONS:
•
Light Source: UV LED (365 nm)
•
Power Source: (3) "C" batteries
•
Run Time: 9 hours (continuous)
•
Lamp Head Diameter: 1.62 in (4.11 cm)
•
Length: 8.80 in (22 cm)