VEK MNH1-R24-A
EN - Quick start guide
NOTE
Read the operating instructions
You can find detailed instructions and comprehensive information in
the full user manual for the product. This document is available on the
manufacturer's homepage www.feig.de.
NOTE
Read and keep instructions
Read this document before you use the product for the first time, and
keep it in a safe place for future reference.
NOTE
Maintenance and repairs
This product does not require any maintenance or servicing.
In the event of malfunctions and faults, please contact the vendor or
the manufacturer.
WARNING
Improper use
The device is subject to the manufacturer's guarantee conditions valid
at the time of purchase. The manufacturer will not accept any
responsibility for incorrect manual or automatic parameter settings
performed on a device or the inappropriate use of a device.
Improper repairs
Repairs may only be performed by the manufacturer. Failure to comply
results in endangering the safety of the device and renders the
warranty null and void.
Permitted power sources
The power supply must meet the requirements for safety extra-low
voltage (SELV).
Essential safety equipment
The device may not be used as a safety component as defined by the
Machinery Directive 2006/42/EG, the Construction Products
Regulation 305/2011/EU or other safety regulations. Systems posing a
threat of danger require additional safety equipment.
At the end of its service life, dispose of the product in
accordance with the valid legal specifications.
1 Product overview
Product components
Traffic detector VEK MNH1-R24-A
Plug-in terminal blocks: 1x supply, 1x loops, 2x relays
Quick start guide
Tab. 1: Scope of delivery
VEK MNH1-R24-A QUICK START GUIDE 1.4 EN
Fig. 1: Traffic detector VEK MNH1-R24-A
Index Component
A
DIP switch
B
Loop channel LEDs (red + blue)
C
USB interface
D
Reset button
E
Loop channel input (orange)
F
Relay output 1 (yellow)
G
Mounting device for TS35 DIN rail
H
Relay output 2 (red)
I
AC/DC connector (blue)
Tab. 2: VEK MNH1-R24-A component list
Specifications
Dimensions
Power supply (1x blue, 2-pole)
Protection type
Permitted operating
temperature
Relative humidity
Loop input
•
max. inductivity range
•
recommended inductivity
range
•
operating frequency
•
cable length
•
internal resistance
Signal outputs
•
2x relays
Configuration switch
LED status indicator
1 | 4
22.5 x 79.0 x 81.0 mm (W x H x L,
without terminals)
10 – 30 VDC / 10 – 26 VAC,
max. 2 W (SELV)
IP20
-37 – +70 °C
< 95 % (non-condensing)
1x orange, 2-pole
20 - 700 H (see note 1)
100 – 300 H
30 – 130 kHz
200 m
20 Ω (including cable)
1x yellow+ 1x red, each 3-pole
max. 48 V (AC/DC), 2 A, 60 W,
125 VA (SELV)
min. 1 mA / 5 V (see note 2)
8-pole DIP switch
1x blue + 1x red
SENSORS