The other end must be inserted into the smoke outlet hole of the kitchen, if the
hole is larger or there are gaps between the extensible tube and the smoke
outlet hole, you must cover the possible leaks with a specific glue. To avoid
loss of suction, avoid very tight angles or double inverted angles as much as
possible, see figures 7 and 8.
3. Chimney installation
The chimney of the extractor hood is made up of two pieces, which are
inserted one inside the other to adapt to the height between the ceiling and
the main body of the extractor hood.
a) Measure the distance from the main body of the hood to the ceiling.
b) Insert the section of the upper chimney that has ventilation grilles
inside the lower section of the chimney (the grilles must be visible), and
adjust the total length of the two sections until obtaining the
measurement that there is from the main body of the chimney. hood to
the ceiling.
c) Place the assembly between the main body of the hood and the ceiling,
fix the lower part of the chimney using screws 2 (3.5 x 9.5 mm), see
figure 9.
d) Then fix the upper part of the chimney to support 3 using screws 2 (3.5
x 9.5 mm), see figure 10.
10