Non-contact type magnetic field rotation direction test
(motor rotation direction test).
1. Remove test line from the indicator.
2. Place the indicator above motor and make it parallel to motor
driving shaft body. Make the bottom of indicator face toward
motor driving shaft. The distance from the indicator to motor
shall be no more than 2.5 cm. See below.
3. Press "TEST" button. The power
light turns green, indicating the
indicator is ready for test.
"Clockwise rotation (R)" or
"Counter-clockwise rotation (L)"
indicator light is on, indicating
the motor is in "clockwise
rotation" or "counter-clockwise
rotation". See below.
23