Ep variant
Safety test after working on electrical components
Check connection of protective earth conductor
All protective conductors must be connected correctly.
The blade connectors must be double crimped.
Test of the earth connection
High-voltage test
50
English 9.808-230.0 Rev. 01 (03/20)
1 Retainer disc brush
2 Measuring device
A current of at least 10 A from an AC power source with a
maximum voltage of 12 V is applied to every touchable
metal part that is connected to the protective conductor for
safety reasons one by one via the earth contact of the
mains plug.
Measure the voltage drop between the protective con-
ductor of the mains plug and the touchable metal parts.
Measure the protective conductor resistance at the re-
tainer of the side brush.
Note
The protective conductor resistance is calculated from the
voltage drop and the current and must be ≤ 0.1 ohm.
1 Program selection switch
2 Measuring device
3 Power connection plug
The high-voltage test must take place between the protec-
tive conductor, live conductor and neutral conductor of the
mains plug.
Turn the programme selector switch to the normal
mode position.
Operate the safety switch.
Connect the connections of the mains plug to the short-
circuit coupling.
Connect the measuring device to the short-circuit cou-
pling and start the measurement via the manual trigger.
The test voltage must be a homogenous voltage of max.
50 Hz AC or DC voltage.
The measuring current must not exceed 5 mA.
Test voltage
1500 V alternating voltage
2250 V direct voltage
Test time Test standard
1 s
EN 50106