Mounting (see figure
Unlock the latches 10 and remove the vacuum
top 3.
For dry vacuuming operation, a dust bag 11 (ac-
cessory) should be inserted.
When operating with a dust bag, the folded fil-
ter 12 clogs less fast, the vacuuming perform-
ance is kept up longer and the disposal of dust
becomes easier.
Slide the dust bag into the connection flange as
shown. Make sure that the full length of the dust
filter faces against the inner wall of the con-
tainer 9. Reattach the vacuum top.
Lock the latches 10.
Insert the vacuum hose 8 into the hose connec-
tion piece 7 until it is seated firmly or place it onto
the hose connection piece 7 respectively, and
turn it in clockwise direction to the stop.
Insert the extension tubes firmly into each other.
It is recommended to use static-discharging
hoses with a hose Ø of 19 or 35 mm.
Initial Operation
Observe correct mains voltage: The voltage of
the power source must agree with the voltage
specified on the nameplate of the machine.
Equipment marked with 230 V can also be con-
nected to 220 V.
Symbols
on
Switching on
off
Switching off
Electromagnetic filter cleaning
Operation with remote automatic
switching
Switching On and Off
To start the operation of the vac, set the mode
selector switch 4 to on.
To switch off the vac, set the mode selector
switch 4 to off.
11 • 1 609 929 C41 • TMS • 22.05.02
All manuals and user guides at all-guides.com
Operation with remote automatic
)
A
switching
Set the mode selector switch 4 to the operation
with remote automatic switching symbol.
The vacuum cleaner is switched on automatically
by the power tool connected to the socket 5.
For connecting the power tool, various hose sys-
tems are available as accessories.
To start the operation of the vac, switch on the
power tool connected to the socket 5. The vac-
uum cleaner starts automatically.
To switch off the vac, switch off the power tool.
The vacuum cleaner switches off automatically
approx. 6 seconds later.
The machine is equipped with an electromag-
netic filter cleaning system, which removes dust
adhering to the folded filter 12.
The filter cleaning system must be actuated latest
when the vacuuming performance is no longer
sufficient.
Set the mode selector switch 4 to the symbol
electromagnetic filter cleaning. A possibly con-
nected power tool must be switched off.
The machine vibrates for approx. 10 seconds
and switches off automatically.
Wait shortly before restarting the vacuuming op-
eration so that the dust can settle in the con-
tainer.
The filter cleaning frequency depends on the type
and amount of dust.
With regular usage, the maximum vacuuming
performance is maintained longer.
English - 2
Electromagnetic filter cleaning