Technical data
CZ
General
IP
DE
Max. ambient RH (relative humidity)
Controller
DK
CE marking
Low voltage tests
EMC (electromagnetic compatibility requirements) tests
EE
Power supply
Operating temperature
Storage temperature
ES
Maximum consumption
Pump 1 output
Heating output
FI
Cooling/pump 2 output
3-point control
Valve output
FR
Power connection
Connection terminals
*)
EN 60730-1 Automatic electrical controls for household and similar use
HR
-- Part 1: General requirements
**)
EN 60730-2-1 Automatic electrical controls for household and similar use
-- Part 2-1: Particular requirements for electrical controls for electrical
household appliances
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SK
1 2
Q U I C K G U I D E
IP30 (IP: degree of inaccessibility to active parts of the product
and degree of water)
85% at 20 °C
EN 60730-1* and EN 60730-2-1**
EN 60730-1
230 V AC +10/-15%, 50 Hz
0 °C to +50 °C
-20 °C to +70 °C
75 W
230 V AC +10/-15%, 250 V AC 5 A maximum (L, N, PE)
230 V AC +10/-15%, 250 V AC 5 A maximum (L, N, PE)
230 V AC +10/-15%, 250 V AC 5 A maximum (L, N, PE)
2 TRIACS => 75 W max
230 V AC ±10%,
1 m cable with europlug
Up to 4.0 mm² solid, or 2.5 mm² fl exible with ferrules
Usable in all Europe
Declaration of conformity:
We hereby declare under our own responsibility that products dealt
with by these instructions satisfy all essential demands linked to the
R&TTE 1999/5/CE Directive dated March 1999.
0682