Malfunction
No speed difference
between level I and
level II
Motor is not running
Running time of a fully
charged battery is too
short and / or blades
are getting hot
No data displayed on
the charging status
display
The control light of
the charging station in
not on
When the battery is
flat the light of the
charging station does
not change from green
to red
18
Cause
Faulty motor and / or elec-
tronics
Battery is dead
Contacts dirty
Faulty battery
Smell of burning from
the motor housing. Motor
burned out.
Faulty motor and / or elec-
tronics
Clipperhead blocked
Clipper blades were not
oiled sufficiently
Dead, not fully charged or
defective battery has been
used
Battery exhausted
Faulty battery
Charging station is not con-
nected to the power supply
Charging station is faulty
Contacts of battery and/or
charging station are dirty
Faulty battery
Battery exhausted
Contacts of the charging
station are deformed
Translation of the original instructions / Small animal clipper
Rectification
Notify customer service
Charge battery
Switch clipper off and clean the
contacts
Replace battery
Have motor and / or electronics re-
placed (S)
Have motor and / or electronics re-
placed (S)
Clean and oil clipperhead
Oil clipper blades
Only use intact and completely charged
original battery
Place the battery in the charging
station
Replace battery
Connect the charging station to the
power supply
Have charging station inspected (S)
Clean contacts
Replace battery
Place the battery in the charging
station for at least 20 minutes. Replace
the battery if the charging process fails
to start.
Have the charging station repaired (S)

Publicidad