Descargar Imprimir esta página

Profile 566025107 Manual página 7

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 52
566025107
When fixing the detector back on the mounting
plate do not forget to lock the device on the
mounting plate, by inserting the PIN back in to
the buckle.
Important:
When you hear one beep every minute and a low battery warning appears on
the LCD display, please replace the AA/LR6 batteries immediately. Otherwise, the
detector may not work properly.
III. End-of-life warning
This product has a service life of 10 years. After power-up, the product starts
timing and when it reaches 10 years the unit will give end-of-life warning. You
have to replace the product when this warning is given.
End-of-life warning will be made at least once every minute. If the detector is
powered on or off frequently, it may cause timing error. So please don't power
on or off the detector frequently. And please often check the product's manu-
facturing date, to see whether it has expired.
Important:
When you hear three quick beeps at intervals, it means end of unit life. Please
replace the product with a new one immediately.
IV. Alarm silence
When the detector is in alarm condition and the CO concentration is less than
200 PPM, press and hold the TEST button to silence the alarm. Alarm silence
condition is the same as alarm condition except the buzzer doesn't beep tempo-
rarily. The Alarm indicator still flashes. Alarm silence condition lasts less than 10
minutes. Press the TEST button in alarm silence condition, to go back to Alarm
condition.
EN
7. Installation
V. Location
Install the products in bedroom and living areas. You can also install them in
the places where CO leakage might occur, respecting below installation points.
To make sure people can hear the alarm from all sleeping area, we suggest you
install this product on each level of your home.
To avoid causing damage to the product, to prevent false alarm and to provide
optimum performance, do not install the unit in the following places:
-
Do not install the unit in enclosure space (such as in the kitchen cabinet or
behind the curtain).
-
Do not install the unit in the obstructive place (such as behind the
furniture).
-
Do not install the unit on the floor or in the water channel.
-
Do not install near the door and window.
-
Do not install near fan or air conditioner.
-
Do not install near the vents or flues.
-
Do not install in areas where the temperature can easily decrease to -10°C
or exceed 40°C, unless you especially need to install like this.
-
Do not install in areas where there are a lot of lampblack and dust which
will block up the sensor.
-
Do not install in too damp areas.
-
Do not install near kitchen wares or cooking equipment.
-
Do not install within 6 metres of your central heating boiler or other
sources of heat that burn fuel, or appliances such as a kettle.
-
Do not install the device in a the garage, near the exhaust port of motor
vehicles. Because when your car starts, high concentration of CO will be
discharged and the temporary CO that will not kill lives may cause the
alarm.
-
Place out of the reach of children. When handled by children the sensor
could get damaged.
IMPORTANT: Carbon monoxide is almost as light as air and spreads easily
through rooms and houses. Position the CO detector at around 1.5m above the
ground, not lower!
Only install a carbon monoxide alarm on inside walls. In a bedroom it should be
fitted at 'sleeping height' and in a living room at 'seated height'. Place the CO
detector at eye level, for optimum monitoring.
The alarm must be fitted at least 15 cm from any outside walls and at least 30 cm
from ventilation supply and extraction points.
7