7. Remove the impeller shaft with pulley assembly attached.
8. Remove the damaged impeller (13). Make sure that the
shaft sleeve on the left side of the shaft is not missing.
9. Install the impeller shaft with pulley assembly attached in
the new impeller. Make sure that you replace the retained
shaft sleeve on the left side of the shaft.
English
10. Replace and tighten the remaining nut on the left side
plate assembly, screws on the left side cover and screws
on the pulley assembly.
11. Put the belt and the belt tensioner into position.