Technical data
Parameter
value
Name of the product
Model
Supply voltage [V~] / Power
supply frequency [Hz]
Rated current (of power
supply)
Number and type of batteries
Resolution
Temperature measurement
range [°C]
Temperature measurement
accuracy [°C]
Humidity measurement range
[%]
Humidity measurement
accuracy [%]
CO
concentration
2
measurement range [ppm]
CO
concentration
2
measurement accuracy
Feedback time (t90) [min]
Measurement sampling
frequency [s]
Protection class
Ambient temperature [°C] /
Humidity [%] during operation
Dimensions [Width x Depth x
Height; mm]
Weight [kg]
*
Carbon dioxide concentration values in other ranges are values used as reference.
** At temperature exceeding the 0÷50°C range the device stops performing CO
concentration measurement. The measurement is performed again when the
temperature returns to the 2÷48°C range.
Parameter
value
Thermo hygrometer with carbon dioxide
SBS‐CO‐100
230/50
0.35
3 x AAA 1.5V
Temperature: 0.1 °C
Humidity: 0.1 %
CO
: 1ppm
2
‐30 ÷ 65 (internal probe)
‐40 ÷ 125 (external probe)
±0.3 (for ‐10÷65°C)
±0.5 (other values)
0 ÷ 100 (without condensation)
±3 (for 10 ÷ 90 %, at 25°C)
±4 (other values)
0 ÷ 10000**
±3%±40ppm (for 400 ÷ 2000ppm)*
15
5
II
‐30 ÷ 65 / 0 ÷ 100 ***
105x95x20
0.1
2