3. Close the fuel sources.
Turn the propane/LPG cylinder knob to close
position.
4. Turn the fuel cap vent lever to the "OFF" position.
OFF
WARNING
Gasoline, gasoline vapor and propane/LPG are highly
flammable and explosive.
Fire or explosion can cause severe burns or death.
NOTE:
DO NOT stop the engine by moving choke control to
"START" position.
Always ensure that the propane/LPG cylinder fully
closed when the engine is not in use. If the engine
will not be used for a period of two weeks or longer,
please see the Storage section for proper engine and
fuel storage.

Low Oil Shutdown

If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with
dipstick.
If oil level is between LOW and HIGH mark on
dipstick:
1. DO NOT try to restart the engine.
2. Contact an Authorized Service Dealer.
3. DO NOT operate engine until oil level is corrected.
If oil level is below LOW mark on dipstick:
1. Add oil to bring level to HIGH mark.
2. Restart engine and if the engine stops again a low
oil condition may still exist. DO NOT try to restart
the engine.
3. Contact Customer Service.
4. DO NOT operate engine until oil level is corrected.

Do Not Overload Generator

Overloading a generator in excess of its rated wattage
capacity can result in damage to the generator and to
connected electrical devices.
To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to
stabilize.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.

Changing Fuels

DANGER
Gasoline, gasoline vapor and propane/LPG are highly
flammable and explosive.
Fire or explosion can cause severe burns or death.
DANGER
DO NOT add gasoline to the gasoline tank or connect
the Propane/LPG hose to the generator while the
generator is running.
1.Disconnect all electrical loads from the generator.