6.3 Place of installation
For the minimum distances that must be re-
spected when positioning the appliance with
respect to flammable materials and objects, refer
to the instructions in Fig. 9.
Z
Y2
X1
Model
X1
X2
ELSA NEW 800
300 400
Floors made of flammable material such as wood,
parquet, linoleum, laminate or floors covered
with carpets must be protected by a fireproof
base under the appliance that also protects the
front during cleaning from any falling burning
residues.
The manufacturer declines all responsibility for
any variations in the characteristics of the mate-
rial constituting the floor under the protection.
Set up an accessible technical space
for any maintenance work.
Remember to respect the minimum distance
from flammable materials (X), shown on the
identification plate of the pipes used to make the
chimney (Fig. 10).
Pi = Flammable wall
Pp = Floor protection
004779040 - 21/03/2022
ITALIANO
ENGLISH
X2
Y1
Fig. 9
Y1
Y2
Z
400 1000 mm
DEUTSCH
Pi
X1
6.4 Combustion air
The appliance, during its operation, requires
combustion air.
The inflow of combustion air can be obtained in
the following ways:
• it can come directly from outside with direct
connection to the combustion chamber (Fig.
11).
• it can come from the installation room or suita-
ble adjacent rooms (Fig. 12)
Extraction of combustion air from outside
In this case, a possible alternative may be:
• to connect the combustion air inlet of the ap-
pliance to the air intake using a special pipe
(Fig. 11).
FRANÇAIS
ESPAÑOL
Pi
X
Pp
Fig. 10
43