standards. Turn off electrical power at service entrance before wiring.
* If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
* Do not use the plug and an extension cord other that the ones initially supplied with the hood.
WARNING
1. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

2. GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces
the risk of electric shock by providing an escape wire for the electric current. This appliance is
equipped with a cord with a grounding wire and a grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded.
WARNING -Improper grounding can result in a risk of electric shock.
Consult a qualified electrician if the grounding instructions are not completely understood, or if
there is doubt as to whether the appliance is properly grounded. Do not use an extension cord. If
the power supply cord is too short, have a qualified electrician install an outlet near the appliance
CAUTION: To reduce the risk of fire and to properly exhaust
air, be sure to vent air outside - Do not vent exhaust air into
spaces within walls, ceilings or into attics, crawl spaces, or
garages.
INSTALLATION
Before beginning the installation, we advise you to remove the
aluminium filter , to better handle the hood. Before attaching it,
the outlet exhaust duct for air evacuation to the outside must
be installed. Use an outlet exhaust duct with:
- Minimum possible bends (maximum angle of bend: 90°);
- Certified material (according to local, building and fire regulations);
-and as smooth as possible inside.
It is also advisable to avoid any drastic changes in duct
cross-section (recommended diameter: 6-1/8")
Drill the hole in the wall for the air outlet (6-1/2" diameter)
referring to drawings here on the right where the
measurements for the various possibilities are indicated.
Decide on the position of the hole for the air outlet: The
hole must be in the ceiling, according to your
requirements, but must be in vertical line with your hood.
Bear in mind that the hood can expel air through the top
air outlet only.
Fitting under wall unit
Note 1: Before attaching the hood to the wall unit, drill a
hole of 6 1/2'' diameter into the wall unit.