Specification
Polarity indication: Automatic indication, and '-' indicates
negative
Over range display: '0L' or '-0L'
Sampling time: About 3 times/second., bargraph 10
times/second
Unit display: Function and electricity quantity unit display
Automatic shutdown time: 10 minutes
Power supply: 1.5V AAA battery × 3
Battery under-voltage indication: LCD display symbol
Temperature coefficient: Less than 0.1×accuracy/℃
Operating temperature: 18℃ 〜 28℃
Storage temperature: -10℃ 〜 50℃
3.2. Technical indexes
3.2.1. AC current
Range
60A
600A
1000A
Min. input current: 0.1A AC current
Max. input current: 1000A AC current
Frequency range: 45 〜 65Hz
Resolution
0.01A
0.1A
1A
Accuracy
± (2.5% reading + 8 digits)
29