• Clean the appliance and the interior accessories with a cloth and lukewarm water. After cleaning wipe with
fresh water and rub dry.
• After all components are completely dry put the appliance back into operation.
Replacing the light bulb
The inside light is of LED type. To replace the light bulb, please contact a qualified technician.
Replaceable (LED only) light source to be fitted by a professional only. This product contains a light source of
energy efficiency class F.
Troubleshooting
Caution! Before troubleshooting, disconnect the power supply. Only a qualified electrician or
competent person must perform any troubleshooting not described in this manual.
Important! There are certain sounds that are emitted during normal use (compressor, refrigerant circulation).
Problem
Appliance does not work
Appliance freezes or cools
too much
The food is not frozen
enough.
Heavy buildup of frost on
the door seal.
Unusual noises
Water on the floor
Side panels are hot.
If the malfunction persists, contact the Service Centre.
This information is necessary to help you act quickly and correctly. Write down the necessary values here,
be sure to refer to the rating plate.
Possible cause
Temperature regulation knob is set to
coldest.
Mains plug is not plugged in or is
loose.
Fuse has blown or is defective.
Socket is defective.
Temperature is set to too cold, or the
appliance is running on the coldest
setting.
Temperature is not properly adjusted.
Door was open for an extended
period.
A large quantity of warm food
was placed in the appliance
within the last 24 hours.
The appliance is near a heat source.
Door seal is not airtight.
Appliance is not level.
The appliance is touching the
wall or other objects.
A component, e.g., a pipe, at
the rear of the appliance is
touching another part of the
appliance or the wall.
Water drain hole is blocked.
It's normal. Heat exchange parts are
located at the sides.
Solution
Set the knob to another setting and switch
on the appliance.
Insert mains plug.
Check fuse, replace if necessary.
Mains malfunctions are to be corrected by
an electrician.
Turn the temperature regulator to a warmer
setting temporarily.
Please consult the initial Temperature
Setting section.
Only keep the door open for as long as
necessary.
Turn the temperature regulator to a colder
setting temporarily.
Please consult the section on installation
location.
Carefully dry the leaking sections of the
door seal with a hair dryer (set to a cool
setting). At the same time, shape the
warmed door seal by hand to make sure it
sits correctly.
Re-adjust the feet.
Move the appliance slightly.
If necessary, carefully bend the
component out of the way.
See the Cleaning and Care section.