Descargar Imprimir esta página

Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe Rainfinity 26243 Serie Modo De Empleo

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• During installation of the product by qualified trained
personnel, make sure that the entire fastening surface
is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply
the product and has no weak points.
• The premounted dirt collection screen must be used to
prevent dirt from entering through the pipes. Dirt enter-
ing can affect the function and/or lead to damage to
the functional components of the fitting. Hansgrohe
will not be held liable for any resulting damage.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
4
max. 1 MPa
0,14 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
Assembly (see page 34)
English

Symbol description

Do not use silicone containing acetic acid!
Dimensions (see page 33)
Flow diagram (see page 33)
Spare parts (see page 40)
XXX = Colors
000 = Chrome Plated
140 = Brushed Bronze
670 = Matt Black
700 = Matt White
830 = Polished Nickel
Test certificate (see page 40)

Publicidad

loading