EN
FHCL 604 3G TC / FHCL 755 4G TC / FHTL 604 3G TC / FHTL 604 4G / FHTL 755 4G TC
INSTALLATION
Installation and electrical/gas
connection must only be carried out by
specialized and licensed personnel.
The manufacturer declines any liability for
injury to persons or damage to things due to
failure noncompliance with these provisions.
The gas connection must comply with the
regulations in force in the country at the time
of installation.
W
Ensure that the device is connected
directly to the mains socket. Ensure that
no adapters, no multi-sockets and no
extension cables are used to connect the
device.
Cabinet requirements
This handbook refers to a class 3 built-in gas
hob and type Y for electric part.
The gas pipe must not come into contact with
the sides of any oven under the hob.
For fitted units, the components (plastic
materials and veneered wood) must be
assembled with heat-resistant adhesives (min.
100°C): Unsuitable materials and adhesives
can result in warping and detachment.
The Ventilation of rooms must be in compliance
with local regulation.
The kitchen element must allow sufficient room
for the electrical connections of the appliance.
IMPORTANT: These devices are „Y" type with
respect to the degree of protection against
the dangers of fire. The minimum distance
from the edge appliance is 150 mm for the
side wall, 50 mm for the rear and 700 mm
for any cabinets above it. The appliance is
recommended to be built into 40 mm thick
worktops. In case the dimensions are different,
eventual modifications have to be managed by
the technician.
Note: if a hood is installed above the hob,
for the distance to be respected refer to the
assembly instructions of the hood.
B
MINIMUM DIMENSIONS (MM)
A = 590/750
C = 400
W
If the appliance is not installed above an
oven: arrange a separator baffle.
120
* 120x120 mm
– 8 –
A
B
B = 50
D = 700
120
20 mm
Max 50 mm