About the unit itself
- The PowerCombi may be used only for the purposes specified by the
manufacturer!
- Never use the PowerCombi if housing or cables are damaged!
- Take care that there is a firm position! Always ensure that the PowerCombi is
securely positioned so that it cannot fall over or down!
- Ensure that the PowerCombi is kept out of the reach of children! Dangers may
arise which children are not able to recognise!
- Never operate the PowerCombi in a damp or wet environment!
- Maintenance and repair must only be carried out by a qualified specialist
who is familiar with the dangers involved and aware of the relevant regulations!
- Never place the PowerCombi on a hot surface!
Regarding the starting aid
- Do not lay the cable over sharp-edged objects!
- Do not lay the cable with kinks!
- Do not pull on the cable!
- Lay cables in such a way that no tripping is possible!
- When laying the cable, make sure it cannot be damaged!
- The starting aid function of the PowerCombi is designed for temporary use!
Let the PowerCombi cool down for approx. 5 min. after each start-up process
(max. 4-5 seconds)!
Regarding the inverter
- Highly dangerous 230 V voltage lies against the plug of the inverter! Therefore
the same safety regulations should be observed with its use as apply with all
other appliances which work with this voltage!
- The inverter is only suitable for the operation of 230 V consuming units which
are provided with a so-called Euro-plug! Units with earthing-contact-plugs
must not be connected!
- Do not insert any other objects than the suitable plugs into the socket of the
inverter!
- The blowing of the safety device (fuse) indicates an overload of the inverter!
Observe the max. power output of the unit and connect only consuming-units
with appropriate power consumption!
The frequent blowing of the safety device (e. g. at consuming units with poor
power consumption) indicates a malfunction of the inverter!
In this case send the unit immediately to the service!
- The output voltage of this square-wave inverter can only be measured with a
True-RMS measuring device.
Safety instructions
17