Before storing your vacuum, the collection tank should be emptied and cleaned. The
accessories should be cleaned and stored so they can be readily available when needed.
Store the wet/dry vacuum indoors.
Repairs for this wet/dry vacuum should be performed only by qualified service personnel
using only identical replacement parts.
INSTALLING & CLEANING CARTRIDGE FILTER
INSTALLING CARTRIDGE FILTER
1. Verify that the power cord is
disconnected from the outlet.
2. Remove the power head and place in an
upside-down position.
3. Install the cartridge filter over the filter
cage making sure the cage is completely
covered.
4. Place the filter retainer on the top of
the cartridge filter over the raised lip
and tighten down by turning the retainer
clockwise; do not over-tighten.
STORAGE
REPAIRS
5. Place the power head back onto the
collection tank.
REMOVING & CLEANING CARTRIDGE
FILTER
1. Unlock and remove the filter retainer
by turning the retainer handle
counterclockwise.
2. With the removed power head in an
upside-down position, carefully remove
the cartridge filter from the filter cage.
- 18 -