System Start Up Procedure

Step 1 -
Turn on main water supply to home.
Step 2 -
BB-M101 Volumetric Flow Monitor Set Up.
This device is designed for use with 2.4 GHz Wi-Fi. Ensure that
the installation location has strong Wi-Fi signal.
Turning ON and connecting to Wi-Fi:
• Plug monitor into wall outlet. Watts logo will appear.
• Screen will auto advance to language preferences. Select
language then touch Next.
• Do you want to connect to Wi-Fi now: Yes / I'll do it later,
Select Yes and touch Next (If I'll do it later is selected, the
screen will automatically advance to the Home / Dashboard
screen & have limited operation without Wi-Fi connectivity).
• Accept Terms of Use, Select Agree touch Next.
• Select Wi-Fi Network then touch Connect.
• Enter Wi-Fi network password touch Next.
• Connection Successful touch Okay.
Device Registration
• Enter Zip/Postal Code touch Next.
• Enter Name and Email Address. Touch Next.
• Enter Address and Country. Touch Next.
• Enter Mobile Phone # for Text Notifications. Touch Next.
Confirm mobile number by touching Okay.
• A verification email will be sent from Watts Support to the email
address entered above. Click Verify on the email to finalize
Device Registration.
• Screen will auto advance to the Home / Dashboard Screen:
Step 3 -
Open inlet isolation valve to the ¼ open position.
Home / Dashboard Screen Overview
Date
Wi-Fi
Status
Step 4 -
housing lid to bleed air from the system while it is filling with
water. Stop pressing pressure relief button once water flow from
pressure relief is visible.
Step 5 -
water to flow from hot and cold side of faucets until all air has
been purged from the plumbing system.
Step 6 -
Step 7 -
cold side faucet at full flow for 10 minutes to properly flush new
filter cartridge to prepare it for use. Turn off faucet cold side.
Step 8 -
The system is now ready for use.
NOTICE
Check frequently over the next 24 hours to ensure no leaks
are present.
BB-M101 Volumetric Flow Monitor Operation
The flow monitor and inline flow meter that comes with this sys-
tem is a volumetric flow device that records water volume usage
and alerts the user when the filter cartridge has reached its rated
gallon capacity of 84,480 gallons.
Alerts are sent via email or text if monitor is connected to Wi-Fi.
Alerts are also displayed on the device screen regardless of
Wi-Fi connectivity status.
Once the cartridge has reached 0 gallons remaining, replace
the filter with a new one and reset the BB-M101 volumetric flow
monitor using the New Filter Reset Screen. This resets filter
cartridge life, gallon & day counters to full capacity.
Time
Flow Icon: Appears when water is
flowing through the system
Filter Life Consumed:
Blue to White : As it moves 0% to 100%
Filter Life Remaining:
Blue to White : As it moves 100% to 0%
Gallons Remaining:
Blue to White : As it moves 84,480 to 0
Menu Icon: Takes you to the Menu Screen
C
Notification Icon: Appears when there is an unread alert / notification
11
Press the red pressure relief button on top of filter
Fully open inlet and outlet isolation valves and allow
Check for leaks and repair as needed.
Close hot side faucet and allow water to flow from
Turn on water heater(s).