Equipment Specifications
Minimum/Maximum Operating Temperature*
Minimum/Maximum Operating Pressure*
Maximum Continuous Flow Rate for Lead & PFOA/PFOS Reduction**
Maximum Flow Rate for Chlorine Reduction***
Maximum Flow Rate for Chloramine Reduction***
Inlet and Outlet Connection Size/Type
Unfiltered Water Housing Drain Port Connection Size/Type
Filter Housing Body Material
Inlet Pressure Gauge Port
Inlet Pressure Gauge Included
Swing Bolts (Lid) Material
O-ring (Lid) Material
O-ring (Plumbing Adaptors) Material
Nominal Micron Rating
Filter Housing Anchor Kit Included
Number of Filter Cartridges
Filter Cartridge Media Type
Filter Cartridge End Cap Material/Color
Filter Cartridge Top Endcap Includes Handle
Filter Cartridge O-ring (Dual) Material
Maximum Allowable Filter Cartridge Pressure Drop
Flow Monitor Display Type
Flow Monitor Capacity
Positive Indication of Flow
BB-M101 Alarm Set Points
Flow Monitor Power Supply
No Wi-Fi Connectivity Alarm
Flow Meter Type
Flow Meter Connection Size/Type
Flow Meter Body Material
* Minimum and Maximum Operating Temperatures and Pressures listed above apply to complete system as well as all individual components including filter
housing, filter cartridge and volumetric flow monitor/meter.
** See Certified Substance Reduction for specific flow and reduction claims.
*** Claims are not performance tested or certified by IAPMO. Performance claims are based on independent laboratory and manufacturer's internal test data.
Actual performance is dependent on influent water quality, flow rates, system design and application. Results may vary. See Certified Substance Reduction for
certified chlorine flow and reduction claims.
Flow Rate and Pressure Drop
30
25
20
15
10
5
0
1
2
3
SYSTEM MODEL NO. BB-S101
34 to 125°F / 1 to 52°C (125°F / 52°C at 80psi Maximum Pressure)
Color Touch Screen- % Filter Life Consumed / % Filter Life Remaining / Volume Remaining
Visual Text/Email/on Screen: User Selected @ 50%/90%/95% Filter Life Consumed /
Flow Rate and Pressure Drop
4
5
6
7
Flow Rate (GPM)
25psi to 125psi / 172 kPa to 861 kPa
4 GPM (15 lpm)
13 GPM (49.2. lpm)
7 GPM (26.4 lpm)
1" NPT
½" FNPT
Glass Reinforced Polypropylene
1
⁄
" FNPT Brass Reinforced
4
Yes
304 Stainless Steel
EPDM
EPDM
0.5 Micron Nominal
Yes-
⁄
" Concrete Anchors (X3)
3
8
1
Lead Adsorption Carbon Block
Glass Reinforced Polypropylene/Green
Yes
EPDM
40psi Drop
84,480 Gallons / 319791 Liters (Resettable / Non Programmable)
Yes- Flow Wave Icon On Display
@ 100% Mandatory
115 VAC / 60Hz
Yes- Visual Alarm Icon on Display Screen
Inline Flow Through Turbine Meter
1" x 1" MNPT
Glass Reinforced Polymer
8
9
10
11
6
Low Pressure Drop
The Watts BB-S101 system uses
a large, high capacity carbon block
filter cartridge to ensure the highest
degree of performance while offer-
ing the highest possible flow rate at
the lowest possible pressure drop.
12
Pressure drop testing conducted
at Watts' Peoria, AZ facility using
approximately 73ºF water. Test
results reflect new filter cartridge
flow rate and pressure drop
performance.