Descargar Imprimir esta página

Connections; Gas Connection - Infiniton GGP-1W Manual De Instrucciones

Publicidad

Idiomas disponibles

Idiomas disponibles

EN

Connections

Property damage!
Do not use the cover, gas hose and/or gas control switches to carry or move the product.

Gas connection

Any operation on the gas equipment and systems should be performed by authorized and
competent persons.
Prior to installation, make sure the local distribution conditions (gas type and gas pressure) are
compliant with the settings of the product.
LPG connection
 Be careful that gas hose and gas-reducing valve you will use for the stove should be reliable.
Fix the gas supply hose to the hose nozzle behind the stove and tighten with a hose clamp
and screwdriver (Figure 6). Make sure it is tightened well.
 Length of the gas hose of the stove should not be longer than 1500mm.
 Pressure of the gas-reducing valve to be used for LPG should be 1.5 kg/300mmSS and duly
certificated.
 Hoses old, cracked, softened, hardened and used more than 2 years should be replaced.
 Hoses for connecting the containers to the equipment should comply with TS1846 standard
and should be made of such material as not to be affected by gas.
 Use your stove with 12 kg gas container.
8

Publicidad

loading

Este manual también es adecuado para:

Ggp-4fGgp-3bGgp-w2