4

OPERATION

WARNING
Always wear eye protection.
WARNING
Do not use any attachments or accessories not
recommended by the manufacturer of this product.
4.1

START THE MACHINE

Figure 4.
The machine can not work until the reversing button is
pushed fully to the left or right. Do not operate the machine
at low speeds for extended periods of time.
1. Push reversing button to the left.
2. Push the switch trigger to turn the machine ON (I).
4.2

STOP THE MACHINE

Figure 4.
1. Release the switch trigger to turn the machine OFF (O).
WARNING
Release the switch trigger and let the coupler to come to a
complete stop.
4.3
ADJUST THE TURNING
DIRECTION
Figure 6
The machine has the reversing button (forward/reverse lock)
above the switch trigger to chang the direction of the bit.
1. When the reversing button is on the left side of the switch
trigger, the bit direciton is forward.
2. When the reversing button is on the right side of the
switch trigger, the bit direction is reversible.
3. Put the direction button in the OFF (center lock) position
to help decrease the possibility of accidental start when
not operate.
WARNING
Let the coupler to come to a complete stop before changing
the direction of rotation.
4.4

LED LIGHT

Figure 5.
The LED light illuminates when the trigger is depressed.
It provides extra light for increased visibility.
NOTE
English
5

MAINTENANCE

Do not let brake fluids, gasoline, petroleum-based materials
touch the plastic parts. Chemicals can cause damage to the
plastic, and make the plastic unserviceable.
Do not use strong solvents or detergents on the plastic
housing or components.
Remove the battery pack from the machine before
maintenance.
5.1

CLEAN THE MACHINE

The machine must be dry. Humidity can cause risks of
electrical shocks.
Clear the unwanted material out of the air vent with a
vacuum cleaner.
Do not spray the air vent or put the air vent in solvents.
Clean the housing and the plastic components with a
moist and soft cloth.
6

TECHNICAL DATA

Voltage
No Load Speed
Impact rate
Torque
Weight without battery
Battery model
Charger model
Measured sound pressure
level
Measured sound power level 96 dB(A), K
Vibration
The recommended ambient temperature range:
Item
Appliance storage tempera-
ture range
Appliance operation temper-
ature range
5
CAUTION
CAUTION
WARNING
CAUTION
24 V
-1
0 - 2600 min
-1
0 - 3800 min
220 Nm
0.97 kg
P24B2/P2448B2 and other
BAM series
P2448C and other CAM ser-
ies
85 dB(A), K
= 3 dB(A)
pA
= 3 dB(A)
wA
2
6.25 m/s
, K = 1.5 m/s
Temperature
32°F (0°C) - 113°F (45°C)
32°F (0°C) - 113°F (45°C)
EN