GB
MT
Ensure that the equipment is not
hung up or held by the mains
cable. There is a risk of electric
shock from damaged mains ca-
bles.
Note that, over time, dirt and sand
may collect on the bottom of the
shaft, which could damage the
pump. If the water level is too low,
the silt in the shaft can quickly dry
out and impede the pump when
warming up.
Mains Connection
The pump you have purchases is already
fitted with an earthed plug. The pump is
intended for connection to an earthed
socket at 230 V ~ 50Hz.
Connecting the Pressure Line
The pump is installed
-
Either with a fixed pipeline
-
Or with a flexible hose line.
B
1.
Screw the bracket adapter (10)
onto the pump outlet (3).
2.
Fit the hose over the reducer (9)
and secure it with a hose clamp.
Or use a screw connection
at the bracket adapter (10)
or the reducer (9).
Outlet with 1½" internal thread at the
pump for connection of the bracket
adapter (10)
Outlet with 1½" external thread at the
bracket adapter (10) for connection of
the reducer (9) or a 1½" screw connec-
tion
Outlet with 1½" thread at the reducer
(9) for connection of 1½" hose as
36
All manuals and user guides at all-guides.com
clamp connection
Outlet with 1" external thread at the re-
ducer (9) for connection of a 1" screw
connection
Outlet with 1½" thread at the reducer
(9) for connection of a 1"hose as clamp
connection
Adjustment of the float switch
The ON and OFF switching point of the float
switch can be adjusted by changing the posi-
tion of the float switch in the float switch grat-
ing. Please check the following points before
start of operation.
•
The float switch must be attached so
that the switching point ON level and the
switching point OFF level can be reached
easily and with little expenditure of en-
ergy. Check this by placing the pump into
a vessel filled with water and lift the float
switch carefully by hand and then lower it
again. In this case, you can see whether
the pump switches on and off.
•
Also ensure that the separation distance
between the float switch head and the
float switch latching mechanism is not
too small. In the case of a separation
distance which is too small, trouble-free
functioning cannot be guaranteed.
•
During the adjustment of the float switch,
ensure that the float switch does not con-
tact the floor before the pump switches off.
Attention! Risk of running dry and dam-
age to the device.
Operational start-up
•
Check that the pump is standing
firmly on the bottom of the shaft
or hung up safely.
•
Check whether the pressure line
has been attached correctly and