Descargar Imprimir esta página

Chamberlain LiftMaster PROFESSIONAL CS9100 Instrucciones página 20

Cuadro electrónico

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
CONTROL BOARD CS9100
Single-phase electronic control board for automation of rolling
shutters with incorporated radio receiver.
TECHNICAL DATA:
- Power supply
- Flashing beacon output
- Motor output
- Photoelectric cells
power supply
- Low voltage safety features
and commands
- Operating temperature
- Radio receiver
- Op. transmitters
- Max stored TX codes
- Box dimensions
- Material and Class
TERMINAL BOARD CONNECTIONS:
CN1:
1 : 230 V a/c line input (Phase).
2 : 230 V a/c line input (Neutral).
3 : Dry contact output for Flashing Beacon/Courtesy Light.
4 : Dry contact output for Flashing Beacon/Courtesy Light.
5 : Opening motor output L.
6 : Shared motor output N.
7 : Closing motor output L.
CN2:
1 : Photoelectric cell control and power supply (24 V a/c).
2 : Photoelectric cell control and power supply (GND).
3 : PUL open-close command button input (NA).
4 : Shared GND input.
5 : DS1 safety device input.
6 : DS2 safety device input.
7 : Shared GND input.
8 : DS3 safety device input.
9 : Earth antenna input.
10 : Antenna hot pole input.
OPERATIONAL DATA:
Operation with push-button station:
The following operation is obtained using the low voltage push-
button station (PUL) to control the shutter:
the first press opens the shutter until the end of the motor timer
and the second press closes it; if pressed again before the end
of the motor time, the control unit stops movement whether the
shutter is opening or closing.
A further command restarts motion in the opposite direction.
Operation using different models of Radio Control:
Different models of radio control may be programmed: by
storing a code (1 button) a cyclic step by step operation (Open -
Stop - Close) may be achieved, and by storing two different
codes (2 buttons) separate commands are created, one for
opening and one for closing. Storing three different codes (3 -
buttons) produces three distinct commands: the first for Open,
the second for Stop and the third for Close.
Operation using a 1-button radio control:
The following type of operation is obtained using a radio control
with a single button: the first press controls the opening
movement of the shutter until the motor timer stops. The second
press controls the closing movement of the shutter. If the button
is pressed before the motor stops running, the control unit will
stop the shutter moving and the button will need to be pressed
again to reactivate the motor in the opposite direction.
: 230 V a/c 50-60 Hz 1100 W max.
: 230 V a/c 500 W max.
: 230 V a/c 500 W max.
: 24 V a/c 3 W max.
: 24 V c/c
: -10 to 70 °C
: 433MHz
: 12-18 Bit or Rolling Code
: 75
: 110 x 121 x 47 mm.
: ABS V-0 (IP54).
en
Operation using a 2-button radio control:
The following type of operation is obtained using a radio control
with 2 buttons: the first button ("Up", corresponding to the
opening movement) controls opening until the motor stops
running and the second button ("Down", corresponding to the
closing movement) controls the Closure of the shutter. If the
opening movement is interrupted with another "Up" command,
the motor will continue to run in the upward movement direction.
If, however, the movement is interrupted with a "Down"
command, the control unit will stop the motor.
The procedure is the same for the closing movement phase.
Operation using a 3-button radio control:
The following type of operation is obtained using a radio control
from the 3-button series: The Up button controls the opening
movement until the set motor time has elapsed, the Stop button
makes the shutter stop and the Down button controls the
closure of the shutter. If a stop command is sent during the
opening or closing movement, the control unit causes this
movement to stop. If a command which is the opposite direction
to the current movement is sent during the opening or closing
movement, the control unit causes the shutter to change
direction.
Automatic closing:
The control unit can close the shutter automatically without
sending additional commands.
The selection of this operation mode is described in the Pause
Time programming mode.
DS1 safety device:
The DS1 input anticipates the connection of a general safety
device with contact (NC). If not used, this input must be bridged.
Action is not taken into account during the opening stage but
causes inverted motor action during the closing stage. Another
safety device operating mode is described in the SEL DS1
Programming section.
DS2 safety device:
The DS2 input anticipates the connection of a general safety
device with contact (NC). If not used, this input must be bridged.
Action is not taken into account during the opening stage but
causes inverted motor action during the closing stage. Another
safety device operating mode is described in the SEL DS2
Programming section.
DS3 safety device:
The DS3 input anticipates the connection of a general safety
device with contact (NC). If not used, this input must be bridged.
Action is not taken into account during the opening stage but
causes inverted motor action during the closing stage. Another
safety device operating mode is described in the SEL DS3
Programming section.
Operation with TIMER:
The control unit may be connected to a timer instead of using
the open-close command button (PUL).
Example: at 8:00 a.m. the timer closes the contact and the
control unit opens the shutter; at 6:00 p.m. the timer opens the
contact and the control unit closes the shutter. Between 8:00
a.m. and 6:00 p.m. at the end of the opening phase, the control
unit disables the flashing beacon, the automatic closing stage
and the radio controls.
PROGRAMMING:
SEL button: selects the type of function to be stored; selection
is indicated by a flashing LED.

Publicidad

loading