Fig. 5: Hydraulic plan with Supervision control
ZP
Gear pump
M
Electric motor
ÖF
Oil filter
EF
Air bleeding filter
Approved hydraulic oils
Type
Standard oil
(DS0704440)
Low-temperature oil
(DS0702220)
For further information on adjusting the hy-
draulic unit see separate document: Adjust-
ment instructions for the hydraulic system.
These assembly, operation and maintenance instructions must be kept for the entire period of use!
ZP
ÖF
V1
Lift valve
(retracting/lowering)
V2
Extend valve
(lifting/lowering)
DV1 Lower throttle valve
DV2 Retract throttle valve
Name
Temperature range [°C]
MD Performance
−20 to +50
Hydraulic Oil
AVIATICON HV-CHF -40 to +50
M
EF
DB1 Pressure relief valve Lifting
pressure
DB2 Pressure relief valve feed
RV1 Check valve
Areas of use
Normal areas
Unprotected critical areas (e.g.
low temperatures and draughts)