Descargar Imprimir esta página

Safety Information For Maintenance; General Condition - Novoferm NovoDock L530 Traducción Del Manual De Funcionamiento Original

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 68
Equipment
Control unit
state
function
function of main
switch
emergency off
function
secure against switch-
on
electrical cables/
connections
Hydraulic unit
function
safety devices
oil level
condition/
cleanliness
replace
oil filter
leaks
soiling
damages
connection overview
noises
Hydraulic hoses
damages
leaks
connection overview
replace
Hydraulic cylinders visual inspection
function
damages
leaks
fastenings
soiling
8.1

Safety information for maintenance

Before any maintenance, switch off the main switch
of the control unit and secure it against being
switched on again.
Mount the maintenance support (see chapter  4.6.3 -
Inserting the maintenance support).
A sign with the inscription "Maintenance work" must
be attached during each maintenance task.
If protective covers have been removed, replace
them after maintenance.
Check all screw connections for tightness after main-
tenance and tighten them if necessary.
40 - EN
Activity
Interval
visual inspection,
annually
functional check
visual inspection
daily
functional check
daily
functional check
daily
functional check
daily
functional check
monthly
visual inspection
monthly
visual inspection,
annually
functional check
functional check
daily, annually
functional check
annually
visual inspection
weekly, annually operator, hydraulics specialist
visual inspection
monthly
replacement
every two years
replacement
if soiled
visual inspection
monthly, annually operator, hydraulics specialist
visual inspection
weekly
visual inspection
monthly, annually hydraulics specialist
visual inspection
annually
visual inspection
monthly, annually operator, hydraulics specialist
visual inspection
annually
visual inspection
weekly, annually operator, hydraulics specialist
visual inspection
daily, annually
visual inspection
annually
replacement
every six years
annually
functional check
daily, annually
visual inspection
annually
visual inspection
daily, annually
visual inspection
annually
visual inspection
daily, annually
Personnel
expert/qualified person
operator, skilled electrician
operator, skilled electrician
operator, skilled electrician
operator, skilled electrician
skilled electrician
skilled electrician
expert/qualified person
operator, hydraulics specialist
hydraulics specialist
hydraulics specialist
hydraulics specialist
hydraulics specialist
operator, hydraulics specialist
hydraulics specialist
expert/qualified person
operator, hydraulics specialist
hydraulics specialist
hydraulics specialist
expert/qualified person
operator, hydraulics specialist
hydraulics specialist
operator, hydraulics specialist
hydraulics specialist
operator, hydraulics specialist
8.2

General condition

Carry out a test run and make sure to test all
operating functions:
– lifting
– Extension of the lip leveller
– Lowering
– floating position
– moving back to the resting position
– emergency off function via main switch
These assembly, operation and maintenance instructions must be kept for the entire period of use!
also see
chapter
 8.6
 8.7
 8.8
 8.9

Publicidad