Control
1
2
1 Button ON/OFF motor (stand by)
2 Button for low speed (suction power) selection.
When flashing, it indicates that you must wash the grease
filter.
3 Button for medium speed (suction power) selection.
4 Button for high speed (suction power) selection.
5 Button for intensive speed (suction power) selection It lasts 5
minutes then it returns to medium speed (suction power).
6 Button ON/OFF lighting. Press briefly to switch on or off the
lighting of the hood. Press and hold to adjust the intensity of the
light.
Indicators of filter saturation:
At regular time intervals, the hood indicates the need of
performing filter maintenance.
Button
on with steady light:
Perform grease filter maintenance.
Button
flashing:
Perform activated charcoal filter maintenance.
NOTE: Filter saturation signal is visible within the first minute after
switching off the hood; within this time, the reset of saturation
indicators must be performed.
Reset of filter saturation indicators:
Press and hold the button
Activation of saturation indicator activated charcoal filter:
NOTE: This operation must be performed with the hood off.
This indicator is normally deactivated; press and hold the
button
to activate the function: the button lights up with
steady light.
To deactivate the function, press and hold the button
button lights up flashing.
10
3
4
5
CFM Reduction System
Before operating your hood:
Some States and Provinces of the US & Canada restrict the
maximum exhausting airflow of range hoods.
6
Airflow is measured as cubic feet per minute (CFM).
These maximum levels allowed are detailed in the local code
of your area. Please check local codes to find out if you need
to restrict the maximum airflow of your hood. If your local code
mandates a maximum airflow level below the maximum airflow of
this hood (i.e. 600 CFM), please execute the procedure below to
reduce the maximum airflow.
1
1 Turn the motor OFF.
2 Press the ON/OFF (1) and Intensive speed (5) buttons together
for 3 seconds. You will hear a beep and all control lights will
illuminate for 3 seconds.
This action will Disable speeds 3 and 4 and effectively lower the
Maximum airflow to > 300 CFM.
3 Locate the CFM certification sticker in the hardware pack.
4 Peel and Affix this sticker to a visible area in the blower. This
sticker provides official certification to your local inspector that this
hoods maximum airflow has been reduced to > 300 CFM.
Maintenance
ATTENTION!
Before performing any maintenance operation, isolate
the hood from the electrical supply by switching off at the
connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
Do not spray cleaners directly to the control while cleaning the
Hood.The cooker hood should be cleaned regularly
(at least with the same frequency with which you carry out
, the
maintenance of the fat filters) internally and externally.
Clean using the cloth dampened with neutral liquid detergent. Do
not use abrasive products.
DO NOT USE ALCOHOL!
WARNING
Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to the
motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
5