INSTALLATION INSTRUCTIONS
E-LSN05B-4U
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l'alimentation avant
l'installation.
2.
This luminaire must be installed in accordance with the NEC
or your local electrical code. If you are not familiar with these
codes and requirements, consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre code
électrique local. Si vous n'êtes pas familier avec ces codes et
ces exigences, veuillez contacter un électricien qualifié.
3.
SUITABLE FOR DAMP LOCATIONS.
CONVIENT AUX EMPLACEMENTS HUMIDES..
4.
Min. 90°C supply conductors.
Les fils d'alimentation 90°C min.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
SURFACE MOUNT INSTALLATION-
INDIVIDUAL FIXTURE
NOTE: Fixture can be ceiling or wall mounted.
1. Remove the lens assembly by simultaneously pushing both buttons
at one end of the fixture to release the lens at that end. Repeat at
opposite end of fixture. See Figure 1.
2. Use the fixture housing to mark (2) fastener locations on the
mounting surface at the ends of the fixture. See Figure 2. Drill
holes in mounting surface for attachment with customer supplied
#8 fasteners appropriate for surface.
NOTE: If intending to feed supply wiring from a recessed junction
box, make sure the junction box is centered between the two ends
of the housing.
3. If feeding supply wiring from a junction box:
• NOTE: Junction box cover plate will work with a single gang
junction box or 3" or 4" octagonal junction box.
• Attach (2) supplied junction box cover plates to back wall of
housing by inserting flanges of cover plates through square
holes near center of back wall of housing. Engage the flanges of
the cover plates with the housing by sliding the cover plates to
the side. Thread (2) supplied M3x4 mm retaining screws through
cover plates into housing to retain plates. See Figure 3.
If feeding supply wiring through surface conduit:
• Remove chosen 1/2" knockout on end wall of housing and
attach 1/2" conduit.
following:
www.e-conolight.com
Document:
Created By:
4. Pull supply wiring into fixture housing through center hole in back
wall of housing (if mounting over a recessed junction box) or
through surface conduit.
5. Position mounting slots in housing over mounting locations
prepared in Step 2 and attach housing to mounting surface. See
Figure 4.
6. Make wiring connections per ELECTRICAL CONNECTIONS
section.
7. Reinstall the lens assembly by positioning lens over the housing
and carefully pushing lens towards housing to engage lens
assembly with retention springs. Gently pull on lens assembly to
make sure it is properly retained. See Figure 5.
FIGURE 1
FIGURE 2
FIGURE 3
|
888.243.9445
|
FAX: 262.504.5409
Date
ECR#
Fastener Locations