Descargar Imprimir esta página

Installation Instructions - e-conolight savr E-LSN05B-4U Instrucciones De Instalación

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS

E-LSN05B-4U
SURFACE MOUNT INSTALLATION-
CONTINUOUS ROW MOUNTING
(REQUIRES USE OF E-LSNB-ENDBRKT KITS)
NOTE: Limits on the total number of fixtures to be linked are as follows:
• 120V -13 fixtures MAX
• 208V -22 fixtures MAX
• 240V -25 fixtures MAX
• 1277V -30 fixtures MAX
1. Follow Steps 1-6 under SURFACE MOUNT INSTALLATION-
INDIVIDUAL FIXTURE
2. Remove 1/2" knockout at chosen end of first fixture that will
connect to the next fixture in run. See Figure 6.
3. Remove corresponding knockout in next fixture in run to allow
wiring to pass from first fixture into second fixture.
4. Slide the end-to-end bracket under the first fixture housing.
NOTE: Mounting screw closest to end of fixture that will be
connected to next fixture in run might have to be loosened slightly
to slide connection bracket in place. Retighten screw after siding
connection bracket into position. See Figure 7.
5.
Insert the second fixture into the exposed end of the connection
bracket. See Figure 8.
6. Use second fixture housing to mark (2) fastener locations on the
mounting surface at the ends of the fixture. Drill holes in mounting
surface at marked locations and attach second fixture to mounting
surface with customer supplied #8 fasteners appropriate for the
surface.
7. Repeat Steps 2-6 to mount additional fixtures in run.
8. Use the black/white/green wire harness and connect to the input
wires/driver wires of the first fixture (or previous fixture) in the
run. When dimming, use the purple and pink leads from the wire
harness and make the corresponding connections to the dimming
wires of the first fixture (or previous fixture) in the run. See
Figure 9. All wire connections should be made as shown in the
wiring diagram in Figure 10.
9. Once wiring is completed, pass wiring harness through the
knockouts where the fixture connects to the next fixture and splice
the wiring harness leads onto the same color leads from the driver
for the next fixture. See Figure 11.
10. Use provided self-adhesive cable ties to eliminate any cable
tangles and clutter. See Figure 11.
11. Repeat Steps 8-10 to wire all additional fixtures in run.
12. Reinstall lens assemblies on all fixtures in run by positioning each
lens over the corresponding housing and carefully pushing the
lens towards the housing to engage lens assembly with retention
springs. Gently pull on lens assembly to make sure it is properly
retained. Repeat for all lenses/housings in run. See Figure 12.
FIGURE 4
www.e-conolight.com
|
Document:
Created By:
FIGURE 5
FIGURE 6
FIGURE 7
FIGURE 8
888.243.9445
|